Fujitrans World              

Metadata


Investigators
Name: Shin-ichiro Nakaoka

Organization: National Institute for Environmental Studies

Address: 16-2 Onogawa, Tsukuba, Ibaraki, 305-8506, Japan

Phone: +81-29-850-2554

Email: nakaoka.shinichiro@nies.go.jp
Platform Type
Ship
Vessel Name
M/S Fujitrans World
Geographical Coverage
Western Pacific
Ports of Call
YOKOHAMA

NAGOYA

TAIPEI

LAEM CHABANG

PORT KLANG

SINGAPORE

JAKARTA

MUARA

BATANGAS

TAHARA

AUCKLAND

others
Bounds
North: 35

West: 100

South: -45

East: 180
System Design/CO2 Sensor
Measurement Method: NDIR measurement of dry base xCO2 in marine air

Manufacturer: Kimoto Electric Co., Osaka, Japan.

Model: MOG-701 using LI-7000 CO2 Analyzer by LI-COR

Frequency: 10sec (except during calibration routines)

Accuracy of CO2 Air: 0.1ppm

Precision of CO2 Air: 0.01ppm

CO2 Sensor Calibration:

   Introducing CO2 standards to NIDR every 6 hours (10min each standard, 40 min. total) for air.

Manufacturer of CO2 calibration gases:

   Taiyo Nippon Sanso Corporation, Japan. All of the standard gases are certified by NIES laboratory as WMO traceable standards.

   CO2 gas concentrations are approximately 360, 380, 400, 420ppm for air.
Method References/CO2 in Marine Air
Measurement: yes, every 10 seconds

Location and Height: 30m above sea level 
Atmospheric Pressure
Location: Bridge above sea level (32m)

Manufacturer: COPAL electronics

Model: PG-200

Accuracy: 0.5 hPa

Resolution: 0.1 hPa

Calibration: Calibration is performed every 6 hours by JMA certified barometer.